This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Search for Publication


Year(s) from:  to 
Author:
Keywords (separated by spaces):

The 2014 liver ultrasound tracking benchmark

V De Luca, T Benz, S Kondo, L König, D Lübke, S Rothlübbers, O Somphone, S Allaire, M A Lediju Bell, D Y F Chung, A Cifor, C Grozea, M Günther, J Jenne, T Kipshagen, M Kowarschik, N Navab, J Rühaak, J Schwaab and C Tanner
Physics in Medicine & Biology
Vol. 60, pp. 5571-5599, July 2015

Abstract

The Challenge on Liver Ultrasound Tracking (CLUST) was held in conjunction with the MICCAI 2014 conference to enable direct comparison of tracking methods for this application. This paper reports the outcome of this challenge, including setup, methods, results and experiences. The database included 54 2D and 3D sequences of the liver of healthy volunteers and tumor patients under free breathing. Participants had to provide the tracking results of 90% of the data (test set) for pre-defined point-landmarks (healthy volunteers) or for tumor segmentations (patient data). In this paper we compare the best six methods which participated in the challenge. Quantitative evaluation was performed by the organizers with respect to manual annotations. Results of all methods showed a mean tracking error ranging between 1.4mm and 2.1mm for 2D points, and between 2.6mm and 4.6mm for 3D points. Fusing all automatic results by considering the median tracking results, improved the mean error to 1.2mm (2D) and 2.5mm (3D). For all methods, the performance is still not comparable to human inter-rater variability, with a mean tracking error of 0.5–0.6mm (2D) and 1.2–1.8mm (3D). The segmentation task was fulfilled only by one participant, resulting in a Dice coefficient ranging from 76.7% to 92.3%. The CLUST database continues to be available and the online leader-board will be updated as an ongoing challenge.


Link to publisher's page
@Article{eth_biwi_01219,
  author = {V De Luca and T Benz and S Kondo and L K\"onig and D L\"ubke and S Rothl\"ubbers and O Somphone and S Allaire and M A Lediju Bell and D Y F Chung and A Cifor and C Grozea and M G\"unther and J Jenne and T Kipshagen and M Kowarschik and N Navab and J R\"uhaak and J Schwaab and C Tanner},
  title = {The 2014 liver ultrasound tracking benchmark},
  journal = {Physics in Medicine & Biology},
  year = {2015},
  month = {July},
  pages = { 5571-5599},
  volume = {60},
  number = {},
  keywords = {respiratory motion, ultrasound, tracking, image registration, image guidance, motion estimation, challenge}
}