This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Search for Publication


Year(s) from:  to 
Author:
Keywords (separated by spaces):

Trajectory of coronary motion and its significance in robotic motion cancellation

Ph. Cattin, H. Dave, J. Grunenfelder, G. Székely, M. Turina and G. Zuend
European Journal of Cardio-thoracic Surgery
Vol. 25, pp. 786-790, May 2004

Abstract

Objectives: To characterize remaining coronary artery motion of beating pig hearts after stabilization with an ?Octopus? using an optical remote analysis technique. Methods: Three pigs (40, 60 and 65 kg) underwent full sternotomy after receiving general anesthesia. An 8-bit high speed black and white video camera (50 frames/s) coupled with a laser sensor (60 m resolution) were used to capture heart wall motion in all three dimensions. Dopamine infusion was used to deliberately modulate cardiac contractility. Synchronized ECG, blood pressure, airway pressure and video data of the region around the first branching point of the left anterior descending (LAD) coronary artery after Octopus stabilization were captured for stretches of 8 s each. Several sequences of the same region were captured over a period of several minutes. Computerized off-line analysis allowed us to perform minute characterization of the heart wall motion. Results: The movement of the points of interest on the LAD ranged from 0.22 to 0.81 mm in the lateral plane (x/y-axis) and 0.5?2.6 mm out of the plane (z-axis). Fast excursions (>50 m/s in the lateral plane) occurred corresponding to the QRS complex and the T wave; while slow excursion phases (<50 m/s in the lateral plane) were observed during the P wave and the ST segment. The trajectories of the points of interest during consecutive cardiac cycles as well as during cardiac cycles minutes apart remained comparable (the differences were negligible), provided the hemodynamics remained stable. Inotrope-induced changes in cardiac contractility influenced not only the maximum excursion, but also the shape of the trajectory. Normal positive pressure ventilation displacing the heart in the thoracic cage was evident by the displacement of the reference point of the trajectory. Conclusions: The movement of the coronary artery after stabilization appears to be still significant. Minute characterization of the trajectory of motion could provide the substrate for achieving motion cancellation for existing robotic systems. Velocity plots could also help improve gated cardiac imaging.


Download in pdf format
@Article{eth_biwi_00333,
  author = {Ph. Cattin and H. Dave and J. Grunenfelder and G. Székely and M. Turina and G. Zuend},
  title = {Trajectory of coronary motion and its significance in robotic motion cancellation},
  journal = {European Journal of Cardio-thoracic Surgery},
  year = {2004},
  month = {May},
  pages = {786-790},
  volume = {25},
  number = {},
  keywords = {off-pump, coronary artery bypass, robotics}
}