This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Search for Publication


Year(s) from:  to 
Author:
Keywords (separated by spaces):

Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: A pilot study.

M . Zihlmann, H . Gerber, A . Stacoff, K . Burckhardt, G . Székely, and E . Stüssi
Gait & Posture
Vol. 24, No. 4, pp. 475-481, December 2006

Abstract

The goal of the study was to simultaneously obtain accurate kinematic and kinetic data from a total knee arthroplasty (TKA) during level walking, by coupling force plate data with the kinematics of TKA measured by a movable video-fluoroscopic system. Kinematic and kinetic information of a TKA is crucial for the improvement of implant designs and for the increased longevity of the implant components. Instrumented gait analysis, with skin mounted marker tracking and force plates, is a well-established method for the acquisition of kinematic and kinetic data of TKA in vivo and for non-invasive estimation of joint function. However, resultant moments at the knee joint are inaccurate with this method, due to skin movement artifacts. Video-fluoroscopy reduces these inaccuracies by means of the direct tracking of the implant components with X-ray. However this measuring technique carries disadvantages: it provides only kinematic data, and the image intensifier covers a limited field of view. This paper presents a newly developed measuring technique, which enables a more accurate resultant moments calculation for level walking than could be achieved by conventional instrumented gait analysis.


Download in pdf format
@Article{eth_biwi_00562,
  author = {M . Zihlmann and H . Gerber and A . Stacoff and K . Burckhardt and G . Székely and and E . St\"ussi},
  title = {Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: A pilot study.},
  journal = {Gait & Posture},
  year = {2006},
  month = {December},
  pages = {475-481},
  volume = {24},
  number = {4},
  keywords = {Movable video-fluoroscopy; Level walking; Kinematics and kinetics; Total knee arthroplasty; Force plate data}
}