This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Search for Publication


Year(s) from:  to 
Author:
Keywords (separated by spaces):

3D analysis of bone formation around titanium implants using micro computed tomography (µCT)

R. Bernhardt et al.
Developments in X-Ray Tomography V
2006

Abstract

The quantitative analysis of bone formation around biofunctionalised metallic implants is an important tool for the further development of implants with higher success rates. This is, nowadays, especially important in cases of additional diseases like diabetes or osteoporosis. Micro computed tomography (_CT), as non-destructive technique, offers the possibility for quantitative three-dimensional recording of bone close to the implant's surface with micrometer resolution, which is the range of the relevant bony structures. Within different animal models using cylindrical and screw-shaped Ti6Al4V implants we have compared visualization and quantitative analysis of newly formed bone by the use of synchrotron-radiation-based CT-systems in comparison with histological findings. The SR_CT experiments were performed at the beamline BW5 (HASYLAB at DESY, Hamburg, Germany) and at the BAMline (BESSY, Berlin, Germany). For the experiments, PMMA-embedded samples were prepared with diameters of about 8mm, which contain in the center the implant surrounded by the bony tissue. To (locally) quantify the bone formation, models were developed and optimized. The comparison of the results obtained by SR_CT and histology demonstrates the advantages and disadvantages of both approaches, although the bone formation values for the different biofunctionalized implants are identical within the error bars. SR_CT allows the clear identification of fully mineralized bone around the different titanium implants. As hundreds of virtual slices were easily generated for the individual samples, the quantification and interactive bone detection led to conclusions of high precision and statistical relevance. In this way, SR_CT in combination with interactive data analysis is proven to be more significant1 with respect to classical histology.


Download in pdf format
@InProceedings{eth_biwi_00466,
  author = {R. Bernhardt et al.},
  title = {3D analysis of bone formation around titanium implants using micro computed tomography (µCT)},
  booktitle = {Developments in X-Ray Tomography V},
  year = {2006},
  pages = {631807-1-10},
  volume = {6318},
  editor = {U. Bonse},
  series = {Proc. of SPIE},
  publisher = {SPIE},
  keywords = {}
}